Viessmann · Heat pump troubleshooting
Mounting the strip heater in the supply duct
What is going on
Side mount only. Check the duct area is clear, then cut and fit the heater so it seals to the duct.
Check in this order
- Isolate all power supplies.
- Check the duct is free of obstacles and wiring before cutting.
- Inspect the heater for shipping damage, check the electrical insulators, element wires and connections for tightness.
- Cut an opening in the side of the duct so the heater slips in tightly.
- Insert the heater and use the heater box to mark the screw locations.
- Remove the heater, drill the mounting holes, then re-insert it.
- Fasten with sheet metal screws and keep the heater sealed to the duct.
- Support larger heaters with hangers.
Applies to: Optional electric strip heat accessory
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-WA installation, service and operating instructions, p. 36. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.