Viessmann · Heat pump troubleshooting
Mounting on a curb
What is going on
Use a field-supplied curb bracket with a gravel bed for condensate.
Check in this order
- Slide two mounting bolts into each channel of the curb bracket.
- Line up the mounting screws with the retaining tabs on the unit.
- Set the unit over the bolts and secure it.
- Keep a gravel bed under the unit to absorb condensate.
- Add a concrete foundation if required, and confirm condensate drains freely.
Applies to: Curb installation
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 39. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.