Mount the indoor unit on a wall
What is going on
The indoor unit is wall mounted on a bracket. The supplied screws and rawl plugs are only suitable for concrete. Other wall materials need fixings rated for 100 lb (46 kg) loads.
Check in this order
- Confirm the wall is concrete or use fixings rated for 100 lb (46 kg) on other materials.
- Mark the rawl plug holes using the bracket, about 16 in. (406 mm) apart as shown.
- Drill holes 3/8 in. (10 mm) and insert the supplied rawl plugs.
- Fasten the wall mounting bracket with the supplied screws.
- Hang the indoor unit on the bracket and make sure both tabs lock into the unit.
- Check that the bracket is tight and secure before leaving the unit.
Applies to: Indoor unit installation
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Viessmann Vitocal 100-AW AM2V installation manual, p. 20. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.