Viessmann · Heat pump troubleshooting
Main temperature sensors overview
What is going on
Lists the five temperature sensors on the outdoor unit: room T1, indoor coil T2, outdoor coil T3, outdoor ambient T4, compressor discharge T5. Each is checked by disconnecting it from the PCB and measuring its resistance.
Check in this order
- Disconnect the sensor from the PCB.
- Measure the sensor resistance with a tester.
- Measure each winding of the sensor with the multimeter.
- Compare the reading with the sensor resistance table.
Applies to: DLCSRB outdoor units
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLCSRB Service Manual, p. 53. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.