Viessmann · Heat pump troubleshooting
Installation example 1: heat pump with buffer tank and DHW tank
What is going on
Example layout with one direct heating circuit, one mixed heating circuit, a system buffer tank and a DHW storage tank. This is a conceptual drawing and all piping and components must be field verified.
Likely causes
- Layout is simplified and does not show all required components.
Check in this order
- Connect the indoor unit (A) to the outdoor unit (B) and the system feed (D) with an expansion tank (E) and wye strainer (F).
- Fit the outdoor temperature sensor (C) and the moisture sensor (G).
- Fit the DHW tank (I) with its temperature sensor (H), a temperature and pressure relief valve (J), potable water inlet (K), DHW outlet (M) and DHW recirculation pump (L) as needed.
- Fit the room temperature sensor (N) and the low-temperature heating circuit (O) with its circuit pump (Q), mixing valve (R) and sensor (P).
- Fit the high-temperature heating circuit (S) with its temperature sensor (T) and circuit pump (U).
- Fit the system buffer tank (V).
- Separate underfloor heating systems with non-oxygen-barrier tubing from the heat exchanger secondary side, and use corrosion-resistant materials on the secondary side.
Applies to: Vitocal 100-AW AM2V with buffer tank and DHW tank
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-AW AM2V Technical Data Manual, p. 32. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.