Viessmann · Heat pump troubleshooting

Inspection of the refrigeration installation

Vitocal 100-AW

What is going on

Checks to complete on the refrigeration side during service.

Check in this order

  1. Replace electrical parts only with suitable parts that meet the manufacturer's specifications.
  2. Use only original spare parts for defective components.
  3. Check again for combustible materials and ignition sources around the heat pump.
  4. Confirm ventilation operates and openings are not blocked.
  5. If a hydronic decoupling system is used, check the secondary circuit for refrigerant.
  6. Make sure inscriptions and symbols are clear and legible; replace any that are not.
  7. Route refrigerant lines so they do not contact corrosive substances, unless they are corrosion-resistant or well protected.

Applies to: Refrigeration circuit and enclosure

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 90. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.