Viessmann · Heat pump troubleshooting
Indoor fan speed out of control
What is going on
The indoor fan is protected when its speed stays too low.
Likely causes
- Indoor fan speed below 300 RPM
Check in this order
- If the indoor fan speed stays below 300 RPM for 50 seconds, the fan shuts off and restarts 30 seconds later.
- If this protection engages 3 times during continuous restarts, the unit stops and the LED shows the failure.
Applies to: DLCLRC indoor fan
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-S DLCLRC service instructions, p. 10. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.