Viessmann · Heat pump troubleshooting

Indoor fan speed out of control

Vitocal 100-SDLCLRC

What is going on

The indoor fan is protected when its speed stays too low.

Likely causes

  • Indoor fan speed below 300 RPM

Check in this order

  1. If the indoor fan speed stays below 300 RPM for 50 seconds, the fan shuts off and restarts 30 seconds later.
  2. If this protection engages 3 times during continuous restarts, the unit stops and the LED shows the failure.

Applies to: DLCLRC indoor fan

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal 100-S DLCLRC service instructions, p. 10. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.