Heat pump not heating or cooling as expected

ECO HP

What is going on

The unit is on, but it is not producing heat or cooling as expected.

Likely causes

  • Temperature settings are incorrect.
  • Water flow is too low.
  • Air in the water system, a plugged strainer, a closed valve, or a broken expansion vessel.
  • Water pressure is too low (must be more than 14.5 psi when cold).
  • Water volume in the installation is below the minimum fill level.

Check in this order

  1. Set all parameters in the application settings correctly.
  2. Check that all water circuit shut-off valves are in the correct position.
  3. Check the strainer for blockage.
  4. Remove air from the water system.
  5. Check the pressure and temperature gauge. Confirm pressure is more than 14.5 psi when the water is cold.
  6. Check the expansion vessel for failure.
  7. Check that the water circuit resistance is not too high for the pump.
  8. Confirm the water volume is above the minimum required fill level.

Applies to: ECO HP split air-to-water heat pump

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: ECO HP Heat Pump Application Guide, p. 64. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.