Handling and tilting the outdoor module

Vitocal 100-AW

What is going on

Sharp tilting can let compressor oil enter the refrigerant circuit and cause a start-up failure.

Likely causes

  • Sharp tilt lets compressor oil migrate into the refrigeration circuit.

Check in this order

  1. Do not tilt the outdoor module beyond 30 degrees.
  2. If a tilt beyond 30 degrees is needed, do not exceed 45 degrees and hold it there for no more than about 4 minutes.
  3. Do not press on the outdoor unit jacketing; strong impacts can damage it.
  4. Route wall ducts and protective conduits for piping and wiring without bends and without changing direction.
  5. Run electrical cables without tension.

Applies to: Outdoor unit AM2V 020028, 034043, 051078

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal 100-AW AM2V Technical Data Manual, p. 25. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.