Handling and tilting the outdoor module
What is going on
Sharp tilting can let compressor oil enter the refrigerant circuit and cause a start-up failure.
Likely causes
- Sharp tilt lets compressor oil migrate into the refrigeration circuit.
Check in this order
- Do not tilt the outdoor module beyond 30 degrees.
- If a tilt beyond 30 degrees is needed, do not exceed 45 degrees and hold it there for no more than about 4 minutes.
- Do not press on the outdoor unit jacketing; strong impacts can damage it.
- Route wall ducts and protective conduits for piping and wiring without bends and without changing direction.
- Run electrical cables without tension.
Applies to: Outdoor unit AM2V 020028, 034043, 051078
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-AW AM2V Technical Data Manual, p. 25. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.