Viessmann · Heat pump troubleshooting
General troubleshooting approach and control board measurements
What is going on
Start with the indoor unit display, since most codes show there. The outdoor board shows only a few errors. Use the flow charts for problems without a code. Use a digital multimeter and refer to the wiring diagrams for all board checks.
Check in this order
- Use the diagnostic code tables and the flow charts to find the problem.
- Check the indoor unit display codes first. Check the outdoor board display if it shows a code.
- Tools needed digital multimeter, Phillips and straight screwdrivers, needle-nose pliers, refrigeration gauges.
- Disconnect main power. Remove the outdoor unit top cover.
- Reconnect main power and probe the outdoor board inputs and outputs with the meter, using the wiring diagrams.
- Connect the red probe to the hot signal and the black probe to ground or negative.
- Note that some DC signals are pulsing. The pulse should move steadily whenever a signal is present.
- To check the indoor board, disconnect main power, remove the front cover and control box cover, and carefully remove the board.
- Place the indoor board face up on a plastic surface, not metal. Reconnect power and repeat the measurements.
- Disconnect main power before reinstalling any board to avoid shock and board damage.
Applies to: DLCLRC outdoor units, sizes 36 to 58, with indoor fan coil
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLCLRC Service Manual, p. 16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.