Evaporator freeze and coil temperature protection (no code)
What is going on
In COOLING, the compressor stops when evaporator temperature is below the setting value and the frequency is limited as coil temperature rises. In DRYING, the compressor stops when room temperature is below 50°F (10°C) and restarts above 53.6°F (12°C).
Likely causes
- Evaporator temperature below setting value
- Room temperature below 50°F (10°C) in DRYING mode
Applies to: DLFSOAH09XAK, DLFSOAH18XAK
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLFSOAH service manual, PDF p. 7, 8, 9. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.