Electrical and component checks before energising a flammable refrigerant system
What is going on
Make safety checks before power is restored to any circuit with a fault that could affect safety.
Check in this order
- Discharge capacitors in a way that cannot spark.
- Make sure no live components or wiring are exposed while charging, recovering or purging.
- Confirm earth bonding continuity.
- Replace sealed electrical components instead of repairing them. Replace intrinsically safe components too.
- Check cabling for wear, corrosion, excess pressure, vibration, sharp edges and aging.
- Check that refrigerant pipes are not exposed to corrosive substances unless they are protected.
- Confirm the refrigerant charge matches the room size and that ventilation is clear and working.
- Keep equipment markings legible and correct any that are not.
Applies to: Vitocal 100-AW AM2V
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 9. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.