Drain the DHW tank for service
What is going on
Drain the domestic hot water tank before opening the connections, so the tank and piping can be serviced.
Check in this order
- Turn off power or fuel supply to the DHW tank.
- Close the cold water supply valve to the tank.
- Hook a hose to the tank drain and run it to a drain or outside.
- Open a nearby pressure relief valve or faucet to break the vacuum and speed draining.
- When the tank is empty, disconnect the hose and remove the drain fitting.
Applies to: DHW tank connected to the desuperheater circuit
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-WA technical data manual, p. 10. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.