Viessmann · Heat pump troubleshooting
Compressor protection trips
What is going on
Protection functions that stop the compressor or unit. No code is listed on these pages for most of them.
Likely causes
- Compressor discharge temperature above 239°F (115°C) for 5 s
- Compressor high temperature cutout open
- Current above the set value
- Inverter module fault on current, voltage or temperature
- Zero crossing signal outside 6 to 13 ms for 240 s
Check in this order
- Check that the unit restarts after the cutout closes or the fault clears.
- Wait for the 3 min restart delay before retesting.
- For an inverter fault, the matching code shows on the indoor unit display.
Applies to: DLCSRB outdoor units
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLCSRB Service Manual, p. 18-19. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.