Viessmann · Heat pump troubleshooting

Compressor discharge temperature protection trip

Vitocal 100-S

What is going on

Compressor stops if discharge temperature T5 exceeds 239°F (115°C) for 5 seconds.

Likely causes

  • Compressor discharge temperature too high

Check in this order

  1. Read compressor discharge temperature (TP) using the outdoor point check function (press 07).
  2. Check refrigerant charge and line restrictions before restarting.

Applies to: DLCURA outdoor units

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLCURA Service Manual, p. 18. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.