Closed loop piping and antifreeze rules
What is going on
Do not use PVC or CPVC on ground loop connections; these may only be used as condensate lines. The loop and unit must hold at least 25% propylene glycol at all times, or the unit can freeze and damage will not be covered. Purge each branch of the loop at a minimum of 2 ft/s, and use the purge ports for antifreeze charging.
Likely causes
- Antifreeze below 25% propylene glycol
- PVC or CPVC used on loop piping
Check in this order
- Use only non-PVC/CPVC pipe on the loop connections.
- Verify 25% minimum propylene glycol in the unit and loop.
- Purge every loop branch at 2 ft/s minimum.
- Install isolation valves and purge ports for purging and antifreeze charging.
Applies to: Closed loop systems
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-WA technical data manual, p. 14. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.