Viessmann · Heat pump troubleshooting

Choosing the outdoor unit location

Vitocal 100-AW AM2V

What is going on

Pick a spot with good air flow, away from anything that can recirculate or block the coil.

Check in this order

  1. Keep the air flow free so cooled air leaves and warm air comes in.
  2. Do not install in corners, recesses or between walls, because exhaust air can recirculate.
  3. Keep the fan and evaporator clear of strong wind, leaves and snow.
  4. Do not mount under windows, next to bedroom windows, in basement sumps or in ground depressions.
  5. Keep at least 10 ft (3 m) from basement sumps, windows, terraces, gutters, coated surfaces and ventilation intakes.
  6. Keep the exhaust side out of the upwind direction.
  7. Place the unit where it is easy to reach for service.
  8. Consider sound reflection from nearby walls when choosing the spot.

Applies to: Outdoor unit site selection

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 37. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.