Viessmann · Heat pump troubleshooting
Charging and leak testing after refrigerant work
What is going on
Charging adds extra precautions for flammable refrigerant. Keep hoses short and avoid cross-contamination.
Check in this order
- Use separate charging equipment for each refrigerant and avoid cross-contamination.
- Keep hoses and lines as short as possible.
- Place cylinders in the position the cylinder instructions give.
- Earth the refrigerating system before charging.
- Do not overfill the system.
- Pressure-test with the correct purging gas before recharging.
- Leak-test after charging and before commissioning.
- Leak-test again before leaving the site.
- Label the system when charging is complete.
Applies to: Vitocal 100-AW AM2V refrigerant circuit
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 10. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.