Application C3 DHW-priority operation

ECO HP

What is going on

Two space-heating zones use circulators through the DHW-priority zone panel. One DHW zone is direct piped with a circulator. Space heating is disabled during a DHW combi call.

Check in this order

  1. Pipe the system primary/secondary.
  2. Install a mixing valve so DHW temperatures are limited.
  3. Size zone circulators for the required flow.
  4. Make sure space heat zones can handle supply temperatures up to 149°F, or use mixing valves to control them.
  5. Add more zones with additional zone panels if needed.

Applies to: Application C3 multi-zone space heating with DHW as zone

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: ECO HP Heat Pump Application Guide, p. 54. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.