Application C2 zone valve end switch wiring
What is going on
Zone valve end switches are wired to the heat pump relay board. The figure shows 120 Vac input and a class 2 section. Some wire labels in the figure are not legible.
Check in this order
- Wire the zone valve end switches to the heat pump inputs as shown in Figure 31.
- Provide 120 Vac input to the relay board.
- Add an isolation relay if the system circulator draws more than 0.2A.
Applies to: Application C2 multi-zone space heating
More heat pump guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: ECO HP Heat Pump Application Guide, p. 52. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.