Lennox · Gas fireplace troubleshooting
Sooting or flame too blue - Lennox Elite LDV
What is going on
Long orange flames with black tips and soot on the glass or near the vent cap, or flames that stay blue and see-through.
Likely causes
- Air shutter closed too far (soot)
- Air shutter open too far (blue flame)
- Flames hitting the panels
- Vent run with many offsets
Check in this order
- Safety air shutter adjustment by a qualified tech only. Glass door must be on and sealed. The lever and nearby surfaces are hot.
- Run the burner at least 30 minutes before judging. A new fire starts blue and turns yellow-orange.
- If sooting, first check the flames are not touching the panels and the media is placed right.
- Lever is on the lower right below the door (remove the surround for easier access). Push in = more air (more open). Pull out = less air.
- Sooting or orange flame open the shutter a bit. Flame stays blue: close it a bit. Run a few minutes and check again.
- More offsets in the vent usually need a wider shutter opening. Propane flames that candle or look stringy also need more air.
Applies to: Elite Linear View LDV42N, LDV42P, LDV54N, LDV54P (SIT Proflame DFC control, remote wall receiver)
More gas fireplace guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Lennox Hearth Elite Linear View Direct-Vent Gas Fireplace LDV42/LDV54 Installation Instructions 506011-02 (06/2012), Adjusting the Air Shutter p.32. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.