Lennox · Gas fireplace troubleshooting

Fireplace does not respond to the remote - Lennox Elite LDV

Lennox Elite Linear View LDV42/LDV54

What is going on

Remote not working on the Elite Linear View? Nine times out of ten it's batteries or the little slider on the wall receiver. Start there before you go looking at the fireplace itself. Pressing ON/OFF and getting nothing means the signal isn't reaching the SIT Proflame DFC control, and most of the reasons are simple, cheap and fixable in a couple of minutes.

Likely causes

  • Wall receiver slider not on REMOTE
  • Remote batteries low
  • Receiver batteries low
  • Remote not paired with the receiver
  • Receiver mounted inside a metal box, which kills the radio range

Check in this order

  1. Check the slider on the wall receiver is on REMOTE. ON and OFF are manual positions and the remote is ignored in them.
  2. Press ON/OFF and watch the remote LED. No light or a dim light means replace the 3 AAA batteries.
  3. If the receiver gives 3 beeps on each press, replace its 4 AA batteries.
  4. To pair a new remote, put the slider on REMOTE and press ON/OFF. Three beeps means it paired.
  5. Backup slide the receiver to ON to light the fireplace by hand, which tells you the fireplace itself is fine.
  6. Check the receiver is not inside a metal box. Metal cuts the radio range, so move it or open the box.
  7. Try the remote from closer to the receiver to rule out a range issue.
  8. If it still will not respond with fresh batteries and a paired remote, call a service tech.

Applies to: Elite Linear View LDV42N, LDV42P, LDV54N, LDV54P (SIT Proflame DFC control, remote wall receiver)

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Lennox Hearth Elite Linear View Direct-Vent Gas Fireplace LDV42/LDV54 Installation Instructions 506011-02 (06/2012), Remote Control System p.25-26. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.