Lennox · Gas fireplace troubleshooting

First start-up: pilot slow to light - Lennox Elite LDV

Lennox Elite Linear View LDV42/LDV54

What is going on

New install, first start, pilot won't catch right away. Usually not a fault. The new gas line is full of air, and the Elite LDV control will keep trying to light until gas reaches the pilot. What I normally find is a couple of failed attempts and then it lights. Let it work through its retries, but stay with it and know when to stop. Gas work is for a licensed fitter.

Likely causes

  • Air in the new gas line that has to be purged before gas reaches the pilot
  • Gas shutoff not fully open at the fireplace or the supply
  • Pilot flame not wrapping the flame sensor rod, so the control drops it
  • Leak or restriction in a field joint, found with leak solution

Check in this order

  1. Safety first gas work by a licensed gas fitter only. Shut the gas off at the fireplace shutoff before opening any fittings.
  2. A new gas line is full of air, so the first light-off can take several minutes. Let the control keep retrying.
  3. Watch that the igniter lights the pilot and the pilot flame wraps around the flame sensor rod.
  4. Leak test all factory and field joints with leak solution while it runs. Never use a flame.
  5. If you smell gas at any time, shut it off, ventilate the room and get out.
  6. If it will not light after purging, turn the gas off and call service.
  7. Do not keep cycling the control over and over, since that just pushes more unburned gas into the box.

Applies to: Elite Linear View LDV42N, LDV42P, LDV54N, LDV54P (SIT Proflame DFC control, remote wall receiver)

More gas fireplace guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Lennox Hearth Elite Linear View Direct-Vent Gas Fireplace LDV42/LDV54 Installation Instructions 506011-02 (06/2012), Verifying Appliance Operation p.30-31; Testing Connections p.12. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.