Rinnai · Tankless water heater
Maint monitor KCM maintenance monitor (flow and outlet temperature)
What the display is showing
Information mode on the MC-601-US controller of KCM units that shows two live readings. Nothing is wrong when you use it.
Applies to: Rinnai KCM tankless (RUCS65i/75i, RUS65e/75e)
What to do
- Press and hold Down for 2 seconds and, without letting go, press On/Off. Repeat the same press to leave.
- Press Up or Down until 01 shows the water flow follows in 0.1 gal/min (58 means 5.8 gal/min).
- Press Up or Down until 02 shows the outgoing water temperature follows in °F.
Settings for these units
- RSC supply connection sizes · SENSEI
- RSC water quality limits · SENSEI
- RSC clearances to combustibles · SENSEI
- RSC temperature settings available · SENSEI
- RX supply connection sizes · SENSEI RX/CX
- RX water quality limits · SENSEI RX/CX
Other codes on the same units
- Diag history Maintenance code history viewer (last 9 codes)
- FH Forced high-fire combustion
- FL Forced low-fire combustion
- LOC Controller locked (KCM)
- Mute Controller key beeps on/off
- ON Hot water running (controller installed)
- Priority light Priority light on (this controller is in charge)
- °C/°F Temperature scale switch (Celsius / Fahrenheit)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rinnai KCM Series Manual (U328-0700X04), p.56. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.