Rinnai · Tankless water heater
LOC Controller locked (KCM)
What the display is showing
On the MC-601-US controller of KCM units, a locked controller cycles the display through LOC, the temperature setting, and any active diagnostic code. Locking one controller locks every controller in the system.
Applies to: Rinnai KCM tankless with MC-601-US controller
What to do
- To lock press Priority and Up together for 5 seconds; a beep confirms it.
- To unlock press Priority and Up together for 5 seconds again.
Settings for these units
- RSC supply connection sizes · SENSEI
- RSC water quality limits · SENSEI
- RSC clearances to combustibles · SENSEI
- RSC temperature settings available · SENSEI
- RX supply connection sizes · SENSEI RX/CX
- RX water quality limits · SENSEI RX/CX
Other codes on the same units
- -- Status monitor: power just connected
- Diag history Maintenance code history viewer (last 9 codes)
- FH Forced high-fire combustion
- FL Forced low-fire combustion
- Maint monitor KCM maintenance monitor (flow and outlet temperature)
- Mute Controller key beeps on/off
- ON Hot water running (controller installed)
- Priority light Priority light on (this controller is in charge)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rinnai KCM Series Manual (U328-0700X04), p.55. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.