Rinnai · Tankless water heater
FL Forced low-fire combustion
What the display is showing
Forced Low combustion. Seen only during the gas pressure setting procedure that is done after certain components are replaced. Not part of normal use.
Applies to: Rinnai KCM tankless (RUCS65i/75i, RUS65e/75e) status monitor
Settings for these units
- RSC supply connection sizes · SENSEI
- RSC water quality limits · SENSEI
- RSC clearances to combustibles · SENSEI
- RSC temperature settings available · SENSEI
- RX supply connection sizes · SENSEI RX/CX
- RX water quality limits · SENSEI RX/CX
Other codes on the same units
- (blank) Status monitor: standby
- -- Status monitor: power just connected
- Diag history Maintenance code history viewer (last 9 codes)
- FH Forced high-fire combustion
- LOC Controller locked (KCM)
- Maint monitor KCM maintenance monitor (flow and outlet temperature)
- Mute Controller key beeps on/off
- ON Hot water running (controller installed)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Rinnai KCM Series Manual (U328-0700X04), Diagnostic Information (status monitor) p.56. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.