Rinnai · Tankless water heater

Diag history Maintenance code history viewer (last 9 codes)

Menu / mode display Non-SENSEISENSEI RX/CXSENSEIKCM (RUCS/RUS)

What the display is showing

Service mode on the temperature controller that scrolls through the last nine stored maintenance codes, one after another, flashing each. Nothing is wrong when you use it; it is only a way to read past events. Controllers: MC-91-2 / MCC-91-2 on most models, MC-601 / MCC-601 on RE/REP, the RX/CX controller, and MC-601-US on KCM.

Applies to: Rinnai tankless water heaters, non-SENSEI, SENSEI, SENSEI RX/CX and KCM

What to do

  1. Turn the heater off with the On/Off button.
  2. Press and hold On/Off for 2 seconds, then press Up while still holding On/Off.
  3. The last 9 codes appear and flash one after the other.
  4. To leave, repeat the On/Off + Up press, then press On/Off to turn the heater back on.

Settings for these units

RSC supply connection sizes · SENSEI

ConnectionSize
Gas3/4 in. NPT
Cold inlet3/4 in. NPT
Hot outlet3/4 in. NPT
Condensate drain1/2 in. NPT
Pressure relief valveM33 thread

The PRV and its adapter come in the box; PRV must be rated 150 psi and at least the heater Btu/h.

Condensate drain line must stay at least 1/2 in. over its whole length.

RSC water quality limits · SENSEI

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved CO2Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDSUp to 500 mg/L
ZincUp to 5 mg/L

Damage from water above these limits is not covered by warranty.

Hard water should be treated; use the Service Soon (SS) reminder (parameter 03) for flushing intervals.

Models that show this code

96 models in Non-SENSEI, SENSEI RX/CX, SENSEI, KCM (RUCS/RUS)

C199eC199iCU160eCU160iCU199eCU199iCX160iCX199iCXP160iCXP199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRSC160eRSC160iRSC199eRSC199iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRU80eRU80iRU90eRU98eRU98i

Other codes on the same units

  • A Venturi reset sequence: step A (RX/CX)
  • AdJ Venturi reset sequence: step AdJ (RX/CX)
  • Bluetooth LED blinking Bluetooth LED blinking (push-button pairing mode)
  • Bluetooth LED solid Bluetooth LED solid blue (app pairing mode)
  • Diagnostic history Show last 9 maintenance codes
  • E Venturi reset sequence: step E (code 17 or 52 only)
  • ECL Reset complete
  • End Descaling procedure ended

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), View Diagnostic Information p.72; Rinnai N-Series Residential (100000467) / with Pump (100000508) / Commercial (100000504) / RSC SENSEI (100000773) Installation and Operation Manuals, 5.6 Diagnostic Codes; Rinnai KCM Series Manual (U328-0700X04), p.56. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.