Rinnai · Tankless water heater

Diagnostic history Show last 9 maintenance codes

Menu / mode display SENSEI RX/CX

What the display is showing

Lets a technician page through the last nine stored codes on the controller. LC appears as 00 in this history.

Applies to: SENSEI RX/CX (RX199i, RX180i, RX160i, RX130i, CX199i, CX160i, RXP199i, RXP160i, CXP199i, CXP160i)

What to do

  1. Switch the heater off with the On/Off button.
  2. Hold On/Off for 2 seconds, then press the up arrow together with it.
  3. The nine most recent codes flash one after another.
  4. To leave, repeat the On/Off hold plus up arrow, then switch the heater back on.

Settings for these units

RX supply connection sizes · SENSEI RX/CX

ConnectionSize
Gas3/4 in. MNPT
Cold inlet3/4 in. MNPT
Hot outlet3/4 in. MNPT
Condensate drain1/2 in. MNPT

Vent connection: 2 in. nominal PVC/CPVC/PP or 3 in./5 in. concentric.

Full specs (input, flow, weight) are only on each model's spec sheet, not in this manual.

RX water quality limits · SENSEI RX/CX

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved CO2Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDSUp to 500 mg/L
ZincUp to 5 mg/L

Water damage beyond these limits is not covered by warranty.

Models that show this code

10 models in SENSEI RX/CX

CX160iCX199iCXP160iCXP199iRX130iRX160iRX180iRX199iRXP160iRXP199i

Other codes on the same units

  • AdJ Venturi reset sequence: step AdJ (RX/CX)
  • Bluetooth LED blinking Bluetooth LED blinking (push-button pairing mode)
  • Bluetooth LED solid Bluetooth LED solid blue (app pairing mode)
  • Diag history Maintenance code history viewer (last 9 codes)
  • E Venturi reset sequence: step E (code 17 or 52 only)
  • ECL Reset complete
  • End Descaling procedure ended
  • F Venturi reset sequence: step F

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai SENSEI RX/CX technical guide U362-0875, service procedures. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.