Rinnai · Tankless water heater

Bluetooth LED solid Bluetooth LED solid blue (app pairing mode)

Normal status SENSEI RX/CX

What the display is showing

Pressing and releasing the controller's Bluetooth key turns its LED solid blue. The heater is ready to pair with the Rinnai Central app (professional account). One beep means pairing succeeded; two beeps mean pairing time ran out without a connection.

Applies to: Rinnai SENSEI RX/CX tankless (RX, RXP, CX, CXP)

Settings for these units

RX supply connection sizes · SENSEI RX/CX

ConnectionSize
Gas3/4 in. MNPT
Cold inlet3/4 in. MNPT
Hot outlet3/4 in. MNPT
Condensate drain1/2 in. MNPT

Vent connection: 2 in. nominal PVC/CPVC/PP or 3 in./5 in. concentric.

Full specs (input, flow, weight) are only on each model's spec sheet, not in this manual.

RX water quality limits · SENSEI RX/CX

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved CO2Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDSUp to 500 mg/L
ZincUp to 5 mg/L

Water damage beyond these limits is not covered by warranty.

Models that show this code

10 models in SENSEI RX/CX

CX160iCX199iCXP160iCXP199iRX130iRX160iRX180iRX199iRXP160iRXP199i

Other codes on the same units

  • A Venturi reset sequence: step A (RX/CX)
  • AdJ Venturi reset sequence: step AdJ (RX/CX)
  • Bluetooth LED blinking Bluetooth LED blinking (push-button pairing mode)
  • Diag history Maintenance code history viewer (last 9 codes)
  • Diagnostic history Show last 9 maintenance codes
  • E Venturi reset sequence: step E (code 17 or 52 only)
  • ECL Reset complete
  • End Descaling procedure ended

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Rinnai Troubleshooting TWH Diagnostic Codes (100000652), BLE and App Instructions p.4; Rinnai SENSEI RX Residential Installation and Operation Manual (100000839), 4.12 p.46 and 7.5 p.75. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.