Navien · Tankless water heater

E127 Air pressure sensor (APS) fault

High severity Navien NHW700

What the control is telling you

The APS reads open or shorted, reads pressure while the fan is stopped, or does not answer. Sub code 1 = open (manual reset), 2 = short (auto reset), 3 = bad default value (auto reset), 5 = no answer (manual reset).

Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE

Likely causes

  • APS plug loose or harness broken
  • APS hose off, cracked or blocked
  • Fan turning while the heater is idle
  • Failed APS
  • PCB fault

Test and repair steps

  1. Power off before unplugging connectors or measuring resistance.
  2. Read the sub code in the error history (Information button 2 s).
  3. Reseat the APS plug and the harness at the PCB. Look for broken wires.
  4. Check both APS hoses are on and not cracked or plugged.
  5. Power on and check the APS supply about 5 V DC between red (P7) and black (P8). Signal white (P6) to black (P8) should move between 0.3 and 4.5 V DC with fan speed.
  6. Check the fan does not run while the heater is idle.
  7. Supply good but signal wrong or stuck replace the APS.
  8. Still there after a new APS replace the PCB.

Settings for these units

Models that show this code

13 models in Navien NHW700

NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU

Other codes on the same units

  • E056 Modulating gas valve fault
  • E157 Air volume control fault

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.1 p.88, 7.2 p.90, 7.3.9 p.105, 5.5 p.75. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.