Majestic · Gas fireplace
1 RED Conversion cover missing
What the control is telling you
Command center shows a single red flash when the gas conversion cap is not seen on the control board.
Applies to: 300DVBLN/PSC7, 400DVBLN/PSC7, 500DVBLN/PSC7 (Signature Command)
Likely causes
- NG/LP conversion cap not installed on the control board
Test and repair steps
- Check that the NG/LP conversion cap is fitted on the control board
- Check the control board connections
Other codes on the same units
- 1 BEEP Single beep (confirmation)
- 1 GREEN / 2 sec Pilot lockout - trial for ignition
- 1 RED / 10 sec Low battery
- 1 RED / 2 sec (until reset) Pressure switch failure (power vent only)
- 1 RED-GREEN / 2 sec Pilot lockout - flame loss
- 2 BEEPS Double beep (confirmation)
- 2 RED Spark fail
- 2 RED / 10 sec No or low thermopile power
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Majestic DVBL7 Series Installation and Operating Instructions, p. 41, p. 48. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.