Majestic · Gas fireplace

1 GREEN / 2 sec Pilot lockout - trial for ignition

High severity DVBL7 Signature Command

What the control is telling you

The pilot did not light during the sparking period and the control locked out. Green flash every 2 seconds until reset.

Applies to: 300DVBLN/PSC7, 400DVBLN/PSC7, 500DVBLN/PSC7 (Signature Command)

Likely causes

  • No gas to the pilot
  • Sparker not lighting the pilot
  • Pilot sensor not in the flame

Test and repair steps

  1. Turn the master switch OFF, then ON again to reset
  2. Press ON and watch whether the pilot lights
  3. If it locks out again, go through the no spark / pilot does not light checks
  4. Check gas supply, sparker and sensor position

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Majestic DVBL7 Series Installation and Operating Instructions, p. 41, p. 47. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.