Lifebreath · Hrv
Service indicator Maintenance due (DXPL02)
What the display is showing
The 99-DXPL02 digital control shows a service symbol when the HRV is due for its routine cleaning. It is a reminder, not a failure.
Applies to: 99-DXPL02 digital control
Good to know
- Maintenance interval has run out
What to do
- Kill power at the HRV disconnect before opening the unit. Some units have more than one power feed.
- Clean or wash the filters and the core, check the outside hoods and the condensate drain.
- After the work is done, hold the ON/OFF button for 5 seconds to clear the symbol.
Settings for these units
HRV maintenance intervals · RNC
| Item | How often |
|---|---|
| Outside hoods and bird screen | Monthly (more in winter for snow and frost) |
| Filters (washable) | 4 times a year |
| Core | Twice a year |
| Motors | No maintenance |
| Condensate drain line and P-trap | Once a year |
| Ductwork | Once a year if needed |
| Inside of cabinet wipe-down | Twice a year |
Turn off power at the disconnect before any service.
Models that show this code
1 model in RNC
Other codes on the same units
- 0 Fan speed 0 = standby (DXPL02)
- Dehumidistat light flashing Dehumidistat calling, unit on high speed
- Dehumidistat light steady Dehumidistat satisfied
- OFF Dehumidistat turned off (DXPL02)
- Repeater LED flashing green Wireless repeater: medium link
- Repeater LED red Wireless repeater: no link to main control
- Repeater LED solid green Wireless repeater: strong link
- Timer battery LED red Wireless timer battery low
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Digital Control DXPL02, p. 9; Maintenance Routine, p. 12-13. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.