Lifebreath · Hrv

Dehumidistat light flashing Dehumidistat calling, unit on high speed

Normal status RNC

What the display is showing

On the BC02 or BC03 wall control the dehumidistat light blinks when the house humidity is above the set point. The HRV is forced to high speed ventilation no matter what speed was picked. Normal operation, not a fault.

Applies to: 99-BC02, 99-BC03 wall controls

Good to know

  • Indoor humidity is above the dehumidistat set point

What to do

  1. Nothing to fix if the house is humid. The unit drops back to its old speed once humidity comes down.
  2. If the customer complains about high speed all the time, check the set point. Too low a setting keeps it on high.
  3. Outside the heating season, turn the dehumidistat off by pressing the button until no light is lit.

Settings for these units

HRV maintenance intervals · RNC

ItemHow often
Outside hoods and bird screenMonthly (more in winter for snow and frost)
Filters (washable)4 times a year
CoreTwice a year
MotorsNo maintenance
Condensate drain line and P-trapOnce a year
DuctworkOnce a year if needed
Inside of cabinet wipe-downTwice a year

Turn off power at the disconnect before any service.

Models that show this code

1 model in RNC

RNC5-ES

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Ventilation Controls BC02 / BC03, p. 5-6. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.