Goodman · Heat pump

Yellow 3 flashes Short cycling (older ComfortNet board)

Medium severity Goodman/Amana ComfortNet ASZC/GSZC/DSZC

What the control is telling you

Yellow LED 3 flashes, green and red off: the last 4 cycles each ran under 3 minutes without a protector trip. Same as code 03 on newer boards.

Applies to: Earlier ComfortNet condensers/heat pumps with the PCBHR101-103 or PBBGR101-102 outdoor control (green, yellow and red status LEDs) - ASXC/DSXC/ASZC/DSZC revisions before the PCBHR104 change

Likely causes

  • Intermittent thermostat call
  • Faulty compressor relay on the control

Test and repair steps

  1. Warning: Kill power to the outdoor unit before touching wiring, the compressor terminals or the control.
  2. Check thermostat and wiring for intermittent contact.
  3. Check the compressor relay; replace the control if needed.
  4. Clears after 4 normal cycles or a 24 VAC power cycle.

Models that show this code

24 models in Goodman/Amana ComfortNet ASZC/GSZC/DSZC

ASZC160241ASZC160361ASZC160421ASZC160481ASZC160601ASZC180241ASZC180361ASZC180481ASZC180601DSZC160241DSZC160361DSZC160481DSZC160601DSZC180361DSZC180481DSZC180601GSZC160241GSZC160361GSZC160481GSZC160601GSZC180241GSZC180361GSZC180481GSZC180601

Other codes on the same units

  • EE Outdoor control fault - compressor relay contacts welded
  • Yellow 1 flash Low side fault / low pressure trip / low pressure lockout (older ComfortNet board)
  • Yellow 2 flashes High side fault / high pressure trip / high pressure lockout (older ComfortNet board)
  • Yellow 4 flashes Locked rotor (older ComfortNet board)
  • Yellow 5 flashes Open circuit (older ComfortNet board)
  • Yellow 6 flashes Open start circuit / lockout (older ComfortNet board)
  • Yellow 7 flashes Open run circuit / lockout (older ComfortNet board)
  • Yellow 8 flashes Low or high line voltage (older ComfortNet board)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Goodman ComfortNet ASXC/GSXC/DSXC, ASZC/GSZC/DSZC, AVPTC/MBVC service manual, diagnostic/status LED table (PCBHR101-103, PBBGR101-102) p.65-69. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.