Daikin · Heat pump

Green LED: 1 steady flash Green LED steady flash, no network found

Medium severity DX6VSDZ6VS

What the control is telling you

The unit cannot find a network.

Applies to: DX6VS/DZ6VS outdoor unit and indoor unit control boards

Likely causes

  • Broken or disconnected communication wire(s)
  • Unit installed as a legacy or traditional system

Test and repair steps

  1. Check communication wires (terminal 1 and terminal 2) and replace if needed.
  2. Check the installation type (legacy/traditional or communicating).

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Daikin DX6VS/DZ6VS outdoor unit installation manual, p. 47. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.