All brands · Refrigeration troubleshooting

Won't start cycle

What is going on

If your ice maker won't start a cycle, it usually comes down to power, a stuck signal arm, or a dead motor. The signal arm is the lever that senses the bin level, and if it is stuck in the up position the machine thinks the bin is full. Keep hands out of the mold area while the unit is powered, since the ejector and heater can start.

Likely causes

  • No power to the ice maker
  • Signal arm stuck in the up position
  • Motor shorted or burned out

Check in this order

  1. Check voltage at the ice maker connection
  2. Clear anything blocking the signal arm and make sure it moves freely
  3. Check motor voltage and operation
  4. Replace the motor or module if it is dead
  5. Run a cycle and confirm it starts

More refrigeration guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.