Both sections too warm

What is going on

When both the fresh-food and freezer sections are too warm, something is wrong with the whole cooling system, not just one control. It could be as simple as a dead evaporator fan or a dirty condenser, or something bigger like a leak that has lowered the charge. Start with the easy stuff you can see and hear before you pull out the gauges.

Likely causes

  • Evaporator fan motor dead, so no cold air is moving
  • Cold control set too warm or broken
  • Finned evaporator iced up from a defrost thermostat or timer problem
  • Low charge from a leak
  • Poor clearance around the unit, dirty condenser or ducts
  • Poor door seal, or doors opened a lot

Check in this order

  1. Listen for the fan and replace it if dead
  2. Check the cold control and replace it if it won't cycle correctly
  3. Check the defrost thermostat and timer if the evaporator is iced
  4. Find and repair any leak, then evacuate and recharge. This needs a licensed tech.
  5. Give the unit proper clearance and clean the condenser
  6. Adjust or replace the door gasket
  7. Talk to the customer about door openings and loading

More refrigeration guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.