All brands · Refrigeration troubleshooting

Compressor stops or overloads on start

What is going on

A refrigeration compressor that stops on its overload, or can't start properly, is not always a bad compressor. A clogged drier or cap tube can back liquid refrigerant up into the condenser, which raises head pressure and loads the motor on every start. Confirm the electrical side is safe and sound before you take readings.

Likely causes

  • Clogged drier or cap tube backing liquid refrigerant up into the condenser
  • Resulting high head pressure overloading the motor at start and tripping the overload

Check in this order

  1. Disconnect and lock out power before touching any electrical component or connection
  2. Install gauges and look for high head with low suction, which fits a restriction
  3. Check for a temperature drop across the drier and at the cap tube inlet
  4. Recovery, repair and recharge of the refrigerant circuit should be done by a licensed technician
  5. Replace the drier and clear or replace the cap tube, then verify the compressor starts and runs without tripping

More refrigeration guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.