Unit runs excessively long or continuously

What is going on

Refrigeration unit that runs and runs. It either cannot keep up or something is telling it not to stop.

Likely causes

  • Low refrigerant charge
  • Control contacts stuck or frozen closed
  • Excessive load or poor insulation
  • System undersized
  • Iced evaporator, restriction, dirty condenser, dirty filter or low airflow

Check in this order

  1. Check for a leak and recharge by weight after repairing it, because low charge cuts capacity
  2. Clean the control contacts or replace the control if they stay closed
  3. Find and fix the load or insulation fault, such as door gaskets and heat sources
  4. If the system is undersized, a larger one is the only real fix
  5. Defrost an iced evaporator and find out why it iced
  6. Locate and remove any restriction
  7. Clean the condenser, since a dirty one raises head pressure and run time
  8. Clean or replace the filter, and check evaporator fan motor speed for low airflow

More refrigeration guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.