All brands · Refrigeration troubleshooting
TXV chatters/opens on off cycle (display case door openings)
What is going on
On display cases, a TXV can chatter and open during the off cycle when the doors get opened. Warm air changes the temperature at the bulb after shutdown, and the valve reacts. Confirm this is what is happening before installing anything, and have a licensed technician do refrigerant side work.
Likely causes
- Temperature swings at the bulb after shutdown, from door openings
- Valve responding to warm air while the compressor is off
Check in this order
- Watch the case during an off cycle and note when the valve opens
- Check the bulb location and insulation
- Install a three-way solenoid on the equalizer to hold the valve closed
- Or use a MOP valve to limit the opening
- Recheck the suction line for frost at the next start-up
More refrigeration guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.