All brands · Refrigeration troubleshooting
Runs all the time
What is going on
In my experience a unit that runs all the time is usually fighting something other than a bad sealed system. Check the door seal, the condenser airflow and how the customer is loading it before anything else. A warm room or a lot of ice making will keep any unit running, too. The cold control, the light switch and the charge come after that.
Likely causes
- Poor condenser airflow
- Poor door seal
- Heavy loading or ice making, or a warm room
- Undercharge or overcharge
- Faulty cold control
- Light switch stuck on
- Frequent door openings
Check in this order
- Clear obstructions and relocate the unit if it is boxed in
- Adjust or replace the gasket
- Explain loading and door use to the customer
- If the charge is off, evacuate and recharge to the correct weight (licensed tech)
- Ventilate the room
- Replace a faulty cold control
- Replace the stuck light switch
More refrigeration guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.