All brands · Refrigeration troubleshooting
Runs all the time, too warm
What is going on
If the unit runs all the time and the cabinet is too warm, and there is nothing wrong with the controls, think about ice trapped in the insulation. Once water gets into the cabinet insulation it freezes, and the insulation stops doing its job, so the compressor can never catch up. It is a slow and messy fix, but it can be done right.
Likely causes
- Ice in the cabinet insulation from a cracked shell or failed seal that let moisture in, so the walls lose their insulating value
Check in this order
- Unplug the unit and empty the cabinet
- Melt the ice by leaving the unit off with the doors open
- Dry the insulation thoroughly
- Seal cracks in the shell so moisture cannot get back in
- Restart and check that it holds temperature
More refrigeration guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.