Runs all the time, too cold
What is going on
Runs nonstop and too cold. Thermostat not shutting it off. Box keeps pulling down, product freezes. Two usual suspects. Contacts welded closed or a damaged sensing bulb. Quick test narrows it.
Likely causes
- Faulty thermostat with contacts stuck closed
- Sensing bulb or capillary damaged so the control never sees the set temperature
- Bulb pulled out of its holder or mounted in the wrong spot
- Control knob or setting turned to the coldest position
Check in this order
- Turn the control to its warmest and see if the compressor cuts out.
- Check the setting is where the customer thinks it is.
- With the unit unplugged, test the thermostat contacts for continuity at the warm setting.
- Inspect the bulb and capillary for kinks, breaks or damage.
- Check the bulb is seated in its holder and in the right place.
- Replace the thermostat if it will not open.
- Run it and confirm it cycles off at the setpoint.
More refrigeration guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.