All brands · Refrigeration troubleshooting
Runs all the time, temp normal
What is going on
A unit that runs all the time but still holds a normal temperature is working harder than it should for a reason you can usually see. Start with what is going on at the evaporator, and check the door seal, which can be the real cause of ice. Unplug the unit before reaching into the compartment.
Likely causes
- Ice on the evaporator from a leaking door gasket or poor defrost, which insulates the coil and lengthens run time
- Thermostat bulb not touching the evaporator, so the control reads wrong and keeps the unit running
Check in this order
- Unplug the unit and look at the evaporator for ice buildup
- Check the door gaskets for gaps and replace them if they are worn or not sealing
- Check that the thermostat bulb is held firmly against the evaporator and reposition it if loose
- Run the unit and see whether it cycles off at a normal interval
More refrigeration guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.