All brands · Refrigeration troubleshooting
Pressure rises ≥10 psi within 5 min after recovery
What is going on
Pressure jumps 10 psi or more within 5 min after recovery. Means liquid still hiding in the system. Cold pockets boil off as the pressure equalizes. Recovery is not finished.
Likely causes
- Cold liquid refrigerant pockets still trapped in the system
- Coil or line section that stayed cold and held liquid
Check in this order
- Repeat the recovery pass until the pressure holds
- Chill the recovery cylinder so it pulls harder
- Warm the compressor and cold spots gently
- Watch the gauge for 5 minutes again after each pass
- Keep the cylinder under its fill limit while you work
More refrigeration guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.