Noisy

What is going on

A noisy refrigerator is almost always something mechanical outside the sealed system, such as loose flooring, tubing rubbing the cabinet or a fan hitting its housing. Unplug the unit before reaching behind it or touching the fan or compressor area. Find out when the noise happens, compressor start, running or fan, as that points to the cause.

Likely causes

  • Loose or soft flooring that amplifies vibration
  • Tubing touching the cabinet or other tubing
  • Cabinet not level
  • Drip tray vibrating
  • Fan blade hitting the liner
  • Compressor mechanically grounded against the base or tubing

Check in this order

  1. Unplug the unit before checking anything
  2. Brace the floor or move the unit to a firmer spot
  3. Reposition the tubing so nothing touches
  4. Level the cabinet using the front feet
  5. Move the tray or add a foam pad under it
  6. Move the fan so it clears the liner
  7. Replace the compressor mounts if the compressor is touching the base

More refrigeration guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.