Ice in drip catcher
What is going on
Ice in the drip catcher is one of the easier calls: the heater that keeps the drip tray warm has quit. I see it on units where the tray sits in the cold and the defrost water just freezes there instead of draining. Unplug the unit before touching the heater.
Likely causes
- Defective drip-catcher heater, so meltwater freezes in the tray
- Heater wiring or connection loose or corroded, so the heater gets no power
Check in this order
- Unplug the unit and melt out the ice
- Check the heater leads and connections for damage
- Test the heater for continuity with a meter
- Replace the heater if it is open
- Run a defrost cycle and confirm the tray drains without freezing
More refrigeration guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.