Gradual loss of freezing capacity
What is going on
A freezer that slowly loses its ability to freeze, over weeks or months, points toward a restriction that is building up rather than a sudden failure. Wax in the capillary tube is one known cause, since wax drops out of oil at low temperatures and plugs the small bore. Refrigerant work should be done by a licensed technician, and the system must be recovered before opening it.
Likely causes
- Wax in the capillary tube, which restricts refrigerant flow more as it builds
Check in this order
- Confirm there is a restriction by checking for a low suction pressure and a warm evaporator outlet
- Recover the refrigerant before opening the system (licensed tech)
- Clean or replace the capillary tube and the drier
- Use fresh, low-wax oil
- Evacuate and recharge to the correct weight
- Monitor the freezing capacity over the next few days
More refrigeration guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.