Frost/ice on finned evaporator

What is going on

Frost or ice on the finned evaporator means defrost is failing. Test the pieces in order.

Likely causes

  • Bad defrost timer, so it never calls for defrost, because the motor or contacts are bad
  • Bad defrost heater, which gets no heat to the coil
  • Bad defrost thermostat, which prevents the defrost circuit from completing
  • Leaky door gasket, causing rapid frost buildup
  • Mullion heater dead

Check in this order

  1. Check the evaporator fan first, since a dead fan looks like a defrost problem
  2. Test the timer with a test light
  3. Test the defrost heater electrically (resistance wire) with power off
  4. Replace the heater or thermostat if open
  5. Check the door gaskets for leaks
  6. Check the mullion heater

More refrigeration guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.